- 15. A central air
   15.1. Specifications
   15.2. The instruction on coolant application
   15.3. Remarks at replacement of elements of a central air of air
   15.4. Connection of elements of a central air of air
   15.5. Check of elements of the central air established on the car
   15.6. Installation of manometres for pressure measurement
   15.7. Откачка atmospheric air from a central air
   15.8. Gymnastics of a central air of air
   15.9. Check of level of a coolant
   15.10. Check of operational characteristics
   15.11. Oil for greasing of the compressor of the conditioner
   15.12. Relay check
   15.13. The conditioner compressor
   15.14. The plug of coupling and a pulley of the compressor of the conditioner
   15.15. The coil of excitation of coupling
   15.16. Compressor check on the car
   15.17. The gauge of threefold (double) pressure
   15.18. The fan and the condenser
   15.19. The evaporator
   15.20. Check of the thermostatic gauge (термистора)
   15.21. The air filter of the evaporator
   15.22. The heating and ventilation block
   15.23. The heater block
   15.24. The fan
   15.25. Search and elimination of malfunctions
+ 16. The electric equipment
+ 17. The appendix
+ 18. Electroschemes


944881c0






15.4. Connection of elements of a central air of air Before installation check up a new sealing ring on absence of damages and oil it for greasing of the compressor of the conditioner. Tighten bolts and nuts the demanded moment.


Internal elements of system of cooling are in a condition of chemical stability until the reagent and oil for greasing are used pure, without a moisture. The insignificant quantity of a dirt, a moisture and damp oil can break chemical stability of system and working capacity or to put out of action air central air.

Safety measures

PERFORMANCE ORDER
1. Before separation of elements of a central air of air it is necessary to prepare tools and adaptations for system service so that to leave separated system elements on as smaller time is possible.
2. At separation of components of a central air of air immediately close connections by corresponding covers for an exception of hit of a moisture in system.
3. All spare elements and tubes of a central air of air should be stored in tight packing.
4. Repeatedly do not bend earlier formed tubes.
5. All tools, a coolant distributing a collector, measuring devices and tubes should be stored in a dry and pure place.