Hyundai Accent

Repair and car operation



Hyundai Accent
+ 1. The maintenance instruction
+ 2. The engine
+ 3. Greasing system
+ 4. Cooling system
+ 5. The control, toxicity decrease
+ 6. Fuel system
+ 7. Ignition system
+ 8. Coupling
+ 9. A transmission
+ 10. Axes and power shafts
+ 11. A suspension bracket
+ 12. A steering
+ 13. Brake system
+ 14. A body
- 15. A central air
   15.1. Specifications
   15.2. The instruction on coolant application
   15.3. Remarks at replacement of elements of a central air of air
   15.4. Connection of elements of a central air of air
   15.5. Check of elements of the central air established on the car
   15.6. Installation of manometres for pressure measurement
   15.7. Откачка atmospheric air from a central air
   15.8. Gymnastics of a central air of air
   15.9. Check of level of a coolant
   15.10. Check of operational characteristics
   15.11. Oil for greasing of the compressor of the conditioner
   15.12. Relay check
   15.13. The conditioner compressor
   15.14. The plug of coupling and a pulley of the compressor of the conditioner
   15.15. The coil of excitation of coupling
   15.16. Compressor check on the car
   15.17. The gauge of threefold (double) pressure
   15.18. The fan and the condenser
   15.19. The evaporator
   15.20. Check of the thermostatic gauge (термистора)
   15.21. The air filter of the evaporator
   15.22. The heating and ventilation block
   15.23. The heater block
   15.24. The fan
   15.25. Search and elimination of malfunctions
+ 16. The electric equipment
+ 17. The appendix
+ 18. Electroschemes


944881c0






15.6. Installation of manometres for pressure measurement Connection of manometres

1 – the party with a high pressure;
2 – the party with a high pressure;
3 – low pressure;
4 – a high pressure;
5 – the party with low pressure;
6 – the party with low pressure.

In a central air of air with coolant R-134a there are ports with "quick-detachable connections" adapters. Each adapter represents the plug with a female thread for protection of system from hit of polluting impurity.


PERFORMANCE ORDER
1. Close both valves on a highway.
2. Connect adapters of manometres to corresponding ports.
3. Manually tighten nuts of fastening of hoses of adapters.